PelletVent® for multi-fuel

PelletVent for MultiFuel

Patent-pending venting system designed for stoves that burn multi-fuels or oil fuel. Multi-fuels include: wood pellets, corn, cherry pits, switch grass, coffee husks, walnut shells, soybeans, wheat, sunflower hulls, rapeseed, and sugar beets. (Rated for continuous use flue temperatures up to 570° F.) All PelletVent components that come into contact with flue gases are built with an inner wall of corrosion resistant super-ferritic metal.

PelletVent is uncompromised in attention to detail and performance. Select components are available in black to enhance interior aesthetics. Seams are factory-sealed on all elbows, tees, and fittings. Available in 3” and 4” sizes through hardware and home centers.

  • Specifications
  • Typical Installation
  • Literature

Materials and Construction
PelletVent for multi-fuel is a double-wall pipe with an inner wall of corrosion resistant stainless steel and a galvalume outer wall. Painted black for exterior available.

Clearances
1" clearance to combustibles in the USA and Canada for appliances using multi-fuels or oil.

Diameters
3" and 4"

Listings
c-UL-us Listed to UL 641 (MH8381 and MH14420). ULC Listed to ULC S609, ULC/ORD C441 (CMH1439 and CMH1440).

Typical Installations For PelletVent Pro

Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation.

  • The inner pipe diameter should match the outlet size of the appliance. For installations that require 4" vent and the appliance has a 3" outlet, use an Increaser Adapter 3"-4".
  • Check the appliance manufacturer's installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc.
  • Be fire safe! Maintain the minimum clearances (air-space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer's installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected.

More Typical Installations:

DuraTech Typical Installations

Installation Key
1 Vertical Cap
2 Storm Collar
3 Flashing
4 Cathedral Ceiling Support Box
5 Pipe
6 45° Elbow
7 Appliance Adapter
8 60° Flexible Length
9 90° Elbow
10 Horizontal Cap
11 Wall Thimble
12 Celling Support Firestop Spacer
13 Tee w/Clean-Out Tee Cap
14 Tee Support Bracket

Planning Your Installation:

1 Refer to the Typical PelletVent Pro Installations diagram, on the opposite page, to be familiar with some of the standard PelletVent Pro installations and the required component parts.
2 For a horizontal termination, you will need a Wall Thimble and a Horizontal Cap. The cap must be installed with a 6" clearance to the outside wall (refer to appliance manufacturer's installation instructions for other clearances).
3 For a vertical termination, you will need a Cathedral Ceiling Support Box or Flat Ceiling Support, Attic Insulation Shield (if passing through an attic), Flashing, Storm Collar, and Vertical Cap.
4 Determine the length of PelletVent Pro pipe required. For a vertical termination, measure the pitch of the roof and select the proper flashing. The required minimum height above the roof is 12".
5 Pellet stove inserts in masonry fireplaces will require a flex pipe to snake the vent past the smoke shelf. For transition from PelletVent to an existing DuraPlus Chimney, a Chimney Adapter is available.
6 For vertical rise of PelletVent Pro on the outside of the house, Wall Straps should be used at 4' intervals to provide proper support.
7 Important! Check to be sure that the appliance and the venting system are in compliance with all minimum clearance to combustible requirements.

Planning Your Installation

The following design recommendations are a general guideline to assist in the design and selection of venting components for your installation. Always follow DuraVent Installation instructions before installing your chimney system (found with the cap or support box).

  • Size the vent to meet the appliance manufacturer's specifications.
  • Avoid long runs and excessive use of elbows. Refer to the appliance manufacturer for minimum rise and maximum run configurations for the venting system.
  • Use an Appliance Adapter to ensure a proper connection to appliance. Seal adapter to appliance with high temperature sealant.
  • Use a Single Tee with Clean-Out Tee Cap to facilitate easy cleaning. It is recommended to use a tee off the back of an appliance.
  • In the United States and Canada, maintain the minimum 1" clearance (air space) from vent pipe to combustibles. Use proper support and bracing. Follow local building codes and have your venting system inspected. Be fire safe!